Rheem · Furnace
66 Blower overspeed (BLOWER OVRSPEED)
What the control is telling you
ECM blower running faster than expected - usually means very low static (missing panel/filter) or very high restriction.
Applies to: RGPE/RGLE 2-stage 80+
Likely causes
- Blower door or filter/panels missing
- Duct disconnected
- Severe restriction
Test and repair steps
- Confirm blower door and all panels are in place.
- Check filter and ducts for disconnection or blockage.
- Check blower wheel.
- Verify on unit check airflow (decimal blink = 1 per 100 CFM) against expected.
Settings for these units
- Filter sizes as shipped, upflow (Table 19) · RGPE/RGLE
- Reduced clearance to combustibles (Fig. 3 and 4) · RGPE/RGLE
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: RGPE/RGLE: Table 16 p.49 / Table 20. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.