ICP furnace error codes

19 codes with causes and test steps.

CodeMeaningSeverity
1+2Blower on after power-up (normal)Low
1+5Blower motor lockoutHigh
2Pressure switch did not openMedium
2+5Invalid model selection or setup errorMedium
3Low pressure switch did not close or reopenedMedium
3+5Gas valve fault (modulating valve)High
4Limit circuit faultHigh
4+1Blower motor faultHigh
4+2Inducer motor faultHigh
4+3Low/medium pressure switch open while medium/high switch closedMedium
5Abnormal flame-proving signalCritical
6Ignition proving failureHigh
6+1Ignition lockoutHigh
7Limit circuit lockoutHigh
8Gas heating lockoutCritical
9Medium/high pressure switch or PSR relay did not close or reopenedMedium
10Line voltage polarityMedium
LED offAmber status LED off - no power / blown 3 A fuseHigh
LED steady ONAmber LED on solid - control lockout / wrong model plugHigh

Models covered

G9MAE0601714G9MAE0602120G9MAE0801714G9MAE0802120G9MAE1002122G9MAE1202422

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.