Rinnai · Tankless water heater
03 Power interrupted during bath fill
What the control is telling you
Power to the water heater was lost while a bath fill was in progress.
Applies to: SENSEI, SENSEI RX/CX and non-SENSEI tankless
Likely causes
- Power supply was interrupted during a bath fill
- Faulty PC Board, if the code keeps returning after resets
Test and repair steps
- Close all hot water fixtures.
- Press the ON/OFF button on the controller twice to clear the code.
- If the code comes back after three resets, replace the PC Board.
Settings for these units
- RSC supply connection sizes · SENSEI
- RSC water quality limits · SENSEI
- RSC clearances to combustibles · SENSEI
- RSC temperature settings available · SENSEI
- RX supply connection sizes · SENSEI RX/CX
- RX water quality limits · SENSEI RX/CX
- RX water treatment and flushing by hardness · SENSEI RX/CX
- RX clearances to combustibles · SENSEI RX/CX
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.9. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.