Rheem · Furnace

6 blinks Line and neutral reversed

Medium severity Rheem RGRM/RGTM 90 Plus

What the control is telling you

The STATUS LED on the furnace control flashes 6 times: the control sees hot (L1) and neutral swapped on the 115 V supply. With reversed polarity the control may not be able to prove flame, so the furnace can light and drop out or lock out.

Applies to: Rheem RGRM upflow and RGTM downflow/horizontal two-stage condensing gas furnaces (90 Plus)

Likely causes

  • L1 (hot) and neutral swapped at the furnace junction box or in the supply wiring
  • Wrong polarity at a receptacle or plug-in cord feeding the furnace
  • Poor or missing ground at the furnace or control

Test and repair steps

  1. Warning: Turn off power at the disconnect before opening the junction box; line voltage is present inside.
  2. At the furnace junction box confirm the black supply wire goes to L1 (hot) and the white to neutral, and that the ground wire is connected.
  3. With power on, measure L1 to neutral should read about 115 V, neutral to ground close to 0 V, L1 to ground about 115 V. If neutral to ground reads line voltage, the wires are reversed.
  4. If the furnace is fed from a receptacle, check the receptacle for reversed polarity and correct it.
  5. Correct the wiring, restore power and confirm the STATUS LED returns to steady on and the burners stay lit through a full heat call.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rheem RGRM/RGTM Installation Instructions 92-24161-84-01 (Nature Air RGRM-04*MAES on ManualsLib), Troubleshooting - STATUS LED codes, p.53; Electrical Wiring polarity note. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.