Midea · Heat pump
PH91 Evaporator low temperature protection
What the control is telling you
The indoor coil temperature is too low (freeze protection, normally in cooling).
Applies to: DLCURAH18-60 AAK/ABK single-zone heat pump outdoor units (18K-60K, regular and High Heat)
Likely causes
- Low indoor airflow - dirty filter, blower problem
- Low refrigerant charge
- Low indoor load / low return air temperature
- Indoor coil sensor fault
Test and repair steps
- Check/replace the indoor filter and confirm the blower runs at the correct speed.
- Let the coil thaw if iced.
- Check refrigerant charge and leak-test.
- Check the indoor coil temperature sensor.
Settings for these units
- Outdoor unit minimum clearances · Midea DLCURA ducted single-zone inverter heat pump (outdoor)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Midea/Carrier DLCURA Installation Instructions (Catalog DLCURA-03SI), Table 11 Outdoor Unit Diagnostic Codes, p.19. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.