Lennox · Heat pump

E345 Relay O failure

High severity

What the control is telling you

O relay fault on a component: the pilot relay coil was not energized or its contacts stayed open. S30/S40 alert code 345; unit control shows E345.

Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Likely causes

  • Failed O relay on the control

Test and repair steps

  1. Check for 24 VAC on O during a heat pump heat call.
  2. Replace the component control.
  3. On Lennox variable capacity outdoor units, replace the outdoor control.
  4. Clears after recovery following reset.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.25. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.