E436 Inverter high heat-sink temperature (inverter code 62)
What the control is telling you
Heat sink exceeded the inverter limit; inverter first slows (code 13), then stops the unit. Five times in an hour = lockout. Inverter LED flash code 62 (red 6 flashes, green 2 flashes). S30/S40 thermostat alert code 436 (shown as E436 on the unit control display).
Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems
Likely causes
- Loose screws between heat sink and inverter board
- Blocked heat sink airflow
Test and repair steps
- Warning: Wait five minutes for capacitors to discharge before touching the inverter.
- Tighten the screws holding the heat sink to the inverter board.
- Check the heat sink for debris and airflow obstructions.
- Service urgent disconnect power to the outdoor unit and restart to clear.
- Check inverter LEDs flash code 62 = red 6 flashes, green 2 flashes. Normal inverter LEDs with no fault: red ON, green OFF.
Settings for these units
- Outdoor unit clearances · Lennox EL16KC1
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.40. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.