Lennox · Air conditioner
E423 Inverter CT circuit fault (inverter code 40)
What the control is telling you
The inverter detected a current transformer circuit issue; outdoor unit stops and the anti-short-cycle timer starts. Locks out after 10 strikes in one hour. Inverter LED flash code 40 (red 4 flashes, green off). S30/S40 thermostat alert code 423 (shown as E423 on the unit control display).
Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems
Likely causes
- Inverter current sensing circuit fault
Test and repair steps
- Refer to the outdoor unit service manual for inverter troubleshooting.
- Service urgent disconnect power to the outdoor unit and restart to clear.
- Check inverter LEDs flash code 40 = red 4 flashes, green off. Normal inverter LEDs with no fault: red ON, green OFF.
Settings for these units
- Outdoor unit clearances · Lennox EL16KC1
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.32. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.