Lennox · Air conditioner

E410 Open low pressure switch

Low severity

What the control is telling you

Low side pressure is below the switch limit; the system stops and restarts when the switch closes (dealer information). S30/S40 thermostat alert code 410 (shown as E410 on the unit control display).

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Likely causes

  • Low charge
  • Low indoor airflow / frozen coil
  • Restriction

Test and repair steps

  1. Check operating pressures and charge.
  2. Check indoor airflow and filter.
  3. Clears automatically once fixed.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.30. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.